Configuration and Operation
Page  Operator Instructions blueplanet XPU H / H and XPU H / H PSD
.. Menu structure
Icons used:
0 1
2
3
Menu level (0, 1, 2, 3) Password-protected menu
Display menu Submenu available
Option menu
Menu
level
Display/settings Action in this menu/meaning
Desktop Desktop Press the right arrow key.
0 1
2
3
0
“Measurements” menu Open the menu: Press the right arrow key or the OK key.
0 1
2
3
1
Generator Displays the DC-side voltage, amperage and power.
0 1
2
3
1
Grid Displays the AC-side voltage, amperage and power.
0 1
2
3
1
Unit temperature Displays the temperature in the inverter housing.
0 1
2
3
1
Yield counter
Displays the yield in kWh.
Reset the counter using the “Reset” key.
0 1
2
3
1
Yield today Displays the yield of the current day up to now.
0 1
2
3
1
Total yield Displays the total yield up to now.
0 1
2
3
1
CO2 savings Displays the calculated CO
2
savings (in kg).
0 1
2
3
1
Oper. hours counter
Displays the duration of operation in hours.
Reset the counter using the “Reset” key.
0 1
2
3
1
Oper. time today Displays the duration of operation on the current day.
0 1
2
3
1
Total op. time Displays the total operating time.
0 1
2
3
1
Log data view
Open the menu: Press the right arrow key or
the OK key.
0 1
2
3
2
Daily view
Displays the recorded operating data graphically.
. Select the measured value to be displayed.
Supported measured values:
Grid power P(grid)
DC power per string P(PV) -
DC voltage per string U(PV) -
Unit temperature
. Select a date.
. Press the OK key.
» The display shows the selected data.
Press any key to return to the previous menu.